Install ductwork so that it is in direct contact with i e laying on the ceiling and or truss lower cords.
Insulating hvac ducts in attic.
When insulating hvac ductwork use a foil faced fiberglass insulation with an r 6 or higher r value.
I found instead a vintage 3 ton ac unit with 1 rigid insulation taped all over it and insulated flex duct snaking all over the poorly insulated attic.
No building inspector worth his or her salt is going to let any builder or hvac contractor get away with installing ducts that aren t insulated.
When hvac ducts are installed in a vented attic in a dry climate bury the ducts in attic insulation to protect them from temperature extremes in the unconditioned attic space.
Use metal flex or fiber board ducts that are insulated to.
Unfortunately so many houses especially newer homes end up with ductwork running through the attic.
Duct insulation keeps air that s supposed to be cool cool and air that s supposed to be warm warm.
Purchase duct wrap insulation that complies with the 2009 international energy conservation code iecc standards that specify an r value of 8 for attic ducts and 6 for ducts located anywhere else.
Repeat to insulate the remaining ducts.
Secure the insulation with short strips of foil tape.
Apply a long strip of foil tape along the seam in the insulation.
To install preformed duct insulation start by disconnecting an elbow to expose the end of the duct.
The department of energy claims that the average us home loses hundreds of dollars a year in heating and cooling costs.
Proper duct insulation is a major key to ensuring your home s energy efficiency.
So water is condensing on your ac ducts.
Wrap the insulation around the duct and then pinch the seam closed.
When water condenses and drips into your attic or home it can cause a some serious secondary problems.
Why is this a problem.
Use the type of metallic foil duct tape recommended by the insulation manufacturer to seal and hold the insulation in place.
The rigid insulation was saturated from condensation.
Close to 25 of the energy you use to heat and cool your home disappears through leaky ductwork.
Our heating and ac ducts are 100 within the thermal envelope in the floor trusses above our insulated basement.
Insulated ducts have been the standard for decades now.
But our erv ducts stand alone system not tied in w heat pump and 2 jumper ducts for pressure balancing from bedrooms are suspended above the insulation in our vented attic.
Why is condensation on ductwork a problem.
The greater the temperature extreme between the air inside the duct and the air surrounding the ductwork the greater your need for duct insulation.