As per section 1009 12 1 roof access exception.
Imc roof access hatch minimum size.
1009 16 2 protection at roof hatch openings.
In buildings without an occupied roof access to the roof shall be permitted to be a roof hatch or trap door not less than 16 square feet 1 5 m in area and having a minimum dimension of 24 inches 610 mm.
Permanent ladders installed to provide the required access shall comply with the following minimum design criteria.
Such access shall not require climbing over obstructions greater than 30 inches 762 mm in height or walking on roofs having a slope greater than 4 units vertical in 12 units horizontal 33 percent slope.
Double leaf or two cover roof hatches are also available on the market.
In buildings without an occupied roof access to the roof shall be permitted to be a roof hatch or trap door not less than 16 square feet 1 5m2 in area and having a minimum dimension of 2 feet 610 mm.
The international codes i codes are the widely accepted comprehensive set of model codes used in the us and abroad to help ensure the engineering of safe sustainable affordable and resilient structures.
Also according to clark county building inspection guidelines access doors should allow a lip of one and a half inches at the bottom of each duct and one inch on the top and side.
The international code council icc is a non profit organization dedicated to developing model codes and standards used in the design build and compliance process.
Installation 48 2015 imc study companion code text.
Guards shall be provided where various components that require service and roof hatch openings are located within 10 feet 3048 mm of a roof edge or open side of a walking surface and such edge or open side is located more than 30 inches 762 mm above the floor roof or grade below.
2015 ibc 1011 12 2 roof access states.
According to california mechanical code section 303 9 roof access panels must have a clearance of at least 30 inches allowing personnel to safely access any rooftop equipment or enclosure.
A permanent approved means of access such as a fixed permanent ladder is not required for group r 3 occupancies.
Ladders shall have rung spacing not to exceed 14 inches on center.
The side railing shall extend above the parapet or roof edge not less than 30 inches.
Ladders shall have a toe spacing not less than 6 inches deep.
In buildings without an occupied roof access to the roof shall be permitted to be a roof hatch or trap door not less than 16 square feet in area and having a min.
Distance of 2 feet does this meet the roof hatch has to be 16 square feet or a trap door needs to be that min.
Guards shall be provided where various components that require service and roof hatch openings are located within 10 feet 3048 mm of a roof edge or open side of a walking.